diff options
author | Gavin Shan <shangw@linux.vnet.ibm.com> | 2013-06-05 14:25:50 +0000 |
---|---|---|
committer | Benjamin Herrenschmidt <benh@kernel.crashing.org> | 2013-06-10 08:36:16 +1000 |
commit | b8b3de224f194005ad87ede6fd022fcc2bef3b1a (patch) | |
tree | 9b86b3580c0e615700ecf84653f0364be8164154 /arch | |
parent | c5df457ffe6db7569de9fb856de490b5317c97b4 (diff) |
powerpc/eeh: Don't check RTAS token to get PE addr
RTAS token "ibm,get-config-addr-info" or ibm,get-config-addr-info2"
are used to retrieve the PE address according to PCI address, which
made up of domain/bus/slot/function. If we don't have those 2 tokens,
the domain/bus/slot/function would be used as the address for EEH
RTAS operations. Some older f/w might not have those 2 tokens and
that blocks the EEH functionality to be initialized. It was introduced
by commit e2af155c ("powerpc/eeh: pseries platform EEH initialization").
The patch skips the check on those 2 tokens so we can bring up EEH
functionality successfully. And domain/bus/slot/function will be
used as address for EEH RTAS operations.
Cc: <stable@vger.kernel.org> # v3.4+
Reported-by: Robert Knight <knight@princeton.edu>
Signed-off-by: Gavin Shan <shangw@linux.vnet.ibm.com>
Tested-by: Robert Knight <knight@princeton.edu>
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'arch')
-rw-r--r-- | arch/powerpc/platforms/pseries/eeh_pseries.c | 12 |
1 files changed, 5 insertions, 7 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c index 19506f935737..b456b157d33d 100644 --- a/arch/powerpc/platforms/pseries/eeh_pseries.c +++ b/arch/powerpc/platforms/pseries/eeh_pseries.c @@ -83,7 +83,11 @@ static int pseries_eeh_init(void) ibm_configure_pe = rtas_token("ibm,configure-pe"); ibm_configure_bridge = rtas_token("ibm,configure-bridge"); - /* necessary sanity check */ + /* + * Necessary sanity check. We needn't check "get-config-addr-info" + * and its variant since the old firmware probably support address + * of domain/bus/slot/function for EEH RTAS operations. + */ if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n", __func__); @@ -102,12 +106,6 @@ static int pseries_eeh_init(void) pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n", __func__); return -EINVAL; - } else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE && - ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) { - pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and " - "<ibm,get-config-addr-info> invalid\n", - __func__); - return -EINVAL; } else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE && ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service <ibm,configure-pe> and " |