authorManish Chopra <manishc@marvell.com>2019-12-11 09:59:55 -0800
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2020-01-12 11:22:48 +0100
commitce8cb77bc47c9c1cf4f9faaa2e936d5d42e96c61 (patch)
tree4d1f79f7aff006a763ad8faed8080440c4130653 /drivers/net
parent49961c94b0ee118e5db5fa61e261c136579054aa (diff)
bnx2x: Do not handle requests from VFs after parity
[ Upstream commit 7113f796bbbced2470cd6d7379d50d7a7a78bf34 ] Parity error from the hardware will cause PF to lose the state of their VFs due to PF's internal reload and hardware reset following the parity error. Restrict any configuration request from the VFs after the parity as it could cause unexpected hardware behavior, only way for VFs to recover would be to trigger FLR on VFs and reload them. Signed-off-by: Manish Chopra <manishc@marvell.com> Signed-off-by: Ariel Elior <aelior@marvell.com> Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/net')
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c12
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h1
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c12
3 files changed, 23 insertions, 2 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
index 82960603da33..026c72e62c18 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -9942,10 +9942,18 @@ static void bnx2x_recovery_failed(struct bnx2x *bp)
*/
static void bnx2x_parity_recover(struct bnx2x *bp)
{
- bool global = false;
u32 error_recovered, error_unrecovered;
- bool is_parity;
+ bool is_parity, global = false;
+#ifdef CONFIG_BNX2X_SRIOV
+ int vf_idx;
+
+ for (vf_idx = 0; vf_idx < bp->requested_nr_virtfn; vf_idx++) {
+ struct bnx2x_virtf *vf = BP_VF(bp, vf_idx);
+ if (vf)
+ vf->state = VF_LOST;
+ }
+#endif
DP(NETIF_MSG_HW, "Handling parity\n");
while (1) {
switch (bp->recovery_state) {
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
index 6f6f13dc2be3..ab8339594cd3 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
@@ -139,6 +139,7 @@ struct bnx2x_virtf {
#define VF_ACQUIRED 1 /* VF acquired, but not initialized */
#define VF_ENABLED 2 /* VF Enabled */
#define VF_RESET 3 /* VF FLR'd, pending cleanup */
+#define VF_LOST 4 /* Recovery while VFs are loaded */
bool flr_clnup_stage; /* true during flr cleanup */
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
index a12a4236b143..e9fc3b09dba8 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
@@ -2095,6 +2095,18 @@ static void bnx2x_vf_mbx_request(struct bnx2x *bp, struct bnx2x_virtf *vf,
{
int i;
+ if (vf->state == VF_LOST) {
+ /* Just ack the FW and return if VFs are lost
+ * in case of parity error. VFs are supposed to be timedout
+ * on waiting for PF response.
+ */
+ DP(BNX2X_MSG_IOV,
+ "VF 0x%x lost, not handling the request\n", vf->abs_vfid);
+
+ storm_memset_vf_mbx_ack(bp, vf->abs_vfid);
+ return;
+ }
+
/* check if tlv type is known */
if (bnx2x_tlv_supported(mbx->first_tlv.tl.type)) {
/* Lock the per vf op mutex and note the locker's identity.